Grady Medical is pleased to offer a full line of veterinary infusion pumps to suit your practice needs. Our newest infusion pump additions include the GradyVet 7903B and GradyVet 7904B touchscreen pumps. We also offer universal pre-calibrated GradyVet IV lines. All infusion pumps are tested and pre-calibrated for our GradyVet IV lines before shipping. The GradyVet 9500 and GradyVet 9501 fluid warmers are also a great addition to any practice. We offer in-service support and training with every purchase. Grady Medical is proud to provide competitive pricing and equipment warranties to the veterinarian community while guaranteeing customer satisfaction with every purchase!

GradyVet 7904B Infusion Pump

The new GradyVet 7904B infusion pump is the top of our infusion pump line! It is compatible with any standard IV set and stores up to 5000 treatment histories. The pump has 5 infusion modes with rates from 0.01-1200ml/h. WiFi capability allows for optional connection to a central monitor.

  1. 4.3-inch LCD color touch screen display
  2. Easy calibration
  3. Quiet operation
  4. Horizontal Line placement
  5. Automatic door
  6. Run history up 5000 entries
  7. Pole clamp
  8. USB port to download data
  9. Standby mode
  10. Automatic anti leakage clip
  11. Graphical and dynamical line pressure display
  1. Standard IV sets
  2. 1.8 kg / 3.96 lbs
  3. Flow rate .01 – 2000 ml/hr
  4. Bolus up to 2,000 ml/h
  5. Battery up to 9 hours at 25 ml/hr
  6. Micro mode for 60 d/ml size IV sets
  7. Adjustable KVO  0.01 – 5 ml/h
  8. VTBI 0 – 9999 ml
  9. Drug library
  10. Drop sensor
  11. Standby mode
Grady Medical 7904b Infusion Pump Specification Sheet
Display
4.3 ” TFT Color Screen
Touch Screen
Yes
Infusion Door Design
Automatic
Anti·free Flow Clamp
Automatic
Working Principle
Linear peristalsis
Applicable IV Set Brands
Open system to use univeral IV sets with brand name editable
Concentration Calculate
Automatically
Infusion Modes
2 modes(ml/h which includes rate mode and time mode; body weight)
Relay Mode
Supported
Mirco Mode
100ml/h to 1200m/l, programmable
Rate Range
0.01-1200ml/h with min. increment 0.01ml/h
Accuracy
±5%
Change Rate During Running
Support
VTBI (volume to be infused)
0-9999ml
Volume infused
0-9999ml
Dose Rate units
More than 15 types
KVO Rate
0.01-5.0ml/h, Default Value is 1ml/h

GradyVet 7903B Infusion Pump

The new GradyVet 7903B infusion pump is one of our veterinarian favorites! It is compatible with any standard IV set and stores up to 200 editable brands. The pump has 5 infusion modes with rates from 0.1ml/hr to 2000ml/hr. WiFi capability allows for optional connection to a central monitor.
  1. 4.3 inch color touch screen display
  2. Easy calibration
  3. Quiet operation
  4. Vertical Line placement
  5. Compact design with pop-up handle
  6. Drug library
  7. Run Memory (patient history log)
  8. Available in pole mount or cage holder style
  9. Rapid infusion start based on last treatment
  10. 10 hours battery back-up time
  11. IP44 waterproof
  1. Standard IV sets
  2. Small size 1.45 kg / 3.19 lbs.
  3. Flow rate .01 – 2000 ml/hr
  4. Bolus up to 2,000 ml/h
  5. Battery up to 5 hrs. running at 25 ml/h
  6. KVO at 0.01 ml/h – 5 ml/h
  7. VTBI 0 – 9999 ml
  8. Up to 2,000 ml per hour delivery rate
  9. Battery up to 5hrs at 25 ml/h
Specification Parameters
Infusion apparatus specification
10-60 drips/ml
Infusion Rate
0.1-2000ml/h, minimum step is 0.01ml/h
<100ml/h step is 0.01ml/h,
<1000ml/h step is 0.1ml/h,
≥1000ml/h step is 1ml/h
Infusion accuracy
≤±5%
Drop rate
Infusion set drip pot setting range 10—60 drips/ml, drip rate 1-2000 drops/min, step is 1 drops/min
Drop rate accuracy
≤±5%
Bolus Rate (Bolus)
1-2000ml/h, minimum step is 0.01ml/h
<100ml/h step is 0.01ml/h,
<1000ml/h step is 0.1ml/h,
≥1000ml/h step is 1ml/h
Bolus Rate accuracy
≤±10%
Purge rate
100-2000ml/h, minimum step is 0.1ml/h
<1000ml/h step is 0.1ml/h,
≥1000ml/h step is 1ml/h
Purge rate accuracy
≤±5%
Mirco Mode
100ml/h to 1200m/l, programmable
VTBI
0-9999.99ml, minimum step is 0.01ml
Infusion accuracy
≤±5%
Total Volume Infused
0-9999.99ml
KVO rate
0~5ml/h, minimum step is 0.01ml/h
KVO rate accuracy
≤±10%
Micro mode setting range
0.1~200ml/h
Time Range
1s-99hrs59min59s
Accumulated bubbles
50~1000ul/15min
Acti agentia
0.0199999
Volume
0.01
Conc.
0.0199999
Dose rate
0.019999
Cumulative Bubble
50~1000μl 15
Single fault bolus Volume
≤ 2ml
Anti-bolus volume
≤ 0.2ml
Fuse Type
T2AL 250V
Dimensions
131.5*90*138mm (No fastening clamp, no drop sensor hook)
Weight
single battery with clamp≤1.45kg double batteries with clamp ≤1.55kg
Power Supply
AC power supply
100V-240V AC,50Hz/60Hz,0.25A-0.1A
Input power
50VA
DC power supply
DC 10V-16V,1.5A-0.94A
Battery
Battery quantity
1piece (standard) or 2 pieces (optional)
Battery type
Lithium battery
Rated battery voltage
7.4V
Battery capacity
2600mAh (1 piece battery) or 5200mAh (2 pieces batteries)
Charging time
Off status≤4h(1 piece battery) or ≤8h((2 pieces batteries)
Running time
Use a new battery full of electricity to power: standard (1pc)battery, running at 25 ml/h, the running time from start-up to exhaustion of alarm batteries is not less than 5 hours.

optional(2pcs)battery, running at 25 ml/h, the running time from start-up to exhaustion of alarm batteries is not less than 10 hours.

standard(1pc)battery, running at 2000 ml/h, the running time from start-up to exhaustion of alarm batteries is not less than 2.5hours. optional(2pcs)battery, Running at 2000 ml/h, the running time from start-up to exhaustion of alarm batteries is not less than 5 hours.
Alarm
Alarm signal sound pressure level
When the sound is set at lowest level, alarm signal sound pressure level ≥50dB(A)

When the sound is set at highest level, alarm signal sound pressure level ≤80dB(A)
Alarm information
VTBI near end, VTBI infused, Pressure high, Battery nearly empty, Battery empty, system error, No power supply, Reminder alarm, Standby time expired, KVO finished, Drop sensor connection, Drop error, Empty bottle, Single bubble, Cumulative Bubble, Door Open, Occlusion pre-alarm, Drop in pressure, Drug dose limits exceeded, Backup battery power exhaustion

GradyVet 7902B Infusion Pump

GradyVetflo 7902B Veterinary infusion pump is the state-of-the-art, electronically controlled infusion device that incorporates the latest microprocessor technology with Bolus program.

  1. Small size–save space, easy to carry
  2. Rate Mode, Drop Mode, Time Mode, Piggy Mode
  3. Light and compact
  4. Flexible fixation clamp
  5. Air bubble size adjustable for air alarm
  6. Display of time remains for infusion completion
  7. KVO at 5ml/h
  8. Piggyback infusion function
Specification Parameters
Infusion apparatus specification
10-60 drips/ml
Infusion Rate
0.1-2000ml/h, minimum step is 0.01ml/h
<100ml/h step is 0.01ml/h,
<1000ml/h step is 0.1ml/h,
≥1000ml/h step is 1ml/h
Infusion accuracy
≤±5%
Drop rate
Infusion set drip pot setting range 10—60 drips/ml, drip rate 1-2000 drops/min, step is 1 drops/min
Drop rate accuracy
≤±5%
Bolus Rate (Bolus)
1-2000ml/h, minimum step is 0.01ml/h
<100ml/h step is 0.01ml/h,
<1000ml/h step is 0.1ml/h,
≥1000ml/h step is 1ml/h
Bolus Rate accuracy
≤±10%
Purge rate
100-2000ml/h, minimum step is 0.1ml/h
<1000ml/h step is 0.1ml/h,
≥1000ml/h step is 1ml/h
Purge rate accuracy
≤±5%
Mirco Mode
100ml/h to 1200m/l, programmable
VTBI
0-9999.99ml, minimum step is 0.01ml
Infusion accuracy
≤±5%
Total Volume Infused
0-9999.99ml
KVO rate
0~5ml/h, minimum step is 0.01ml/h
KVO rate accuracy
≤±10%
Micro mode setting range
0.1~200ml/h
Time Range
1s-99hrs59min59s
Accumulated bubbles
50~1000ul/15min
Acti agentia
0.0199999
Volume
0.01
Conc.
0.0199999
Dose rate
0.019999
Cumulative Bubble
50~1000μl 15
Single fault bolus Volume
≤ 2ml
Anti-bolus volume
≤ 0.2ml
Fuse Type
T2AL 250V
Dimensions
131.5*90*138mm (No fastening clamp, no drop sensor hook)
Weight
single battery with clamp≤1.45kg double batteries with clamp ≤1.55kg
Power Supply
AC power supply
100V-240V AC,50Hz/60Hz,0.25A-0.1A
Input power
50VA
DC power supply
DC 10V-16V,1.5A-0.94A
Battery
Battery quantity
1piece (standard) or 2 pieces (optional)
Battery type
Lithium battery
Rated battery voltage
7.4V
Battery capacity
2600mAh (1 piece battery) or 5200mAh (2 pieces batteries)
Charging time
Off status≤4h(1 piece battery) or ≤8h((2 pieces batteries)
Running time
Use a new battery full of electricity to power: standard (1pc)battery, running at 25 ml/h, the running time from start-up to exhaustion of alarm batteries is not less than 5 hours.

optional(2pcs)battery, running at 25 ml/h, the running time from start-up to exhaustion of alarm batteries is not less than 10 hours.

standard(1pc)battery, running at 2000 ml/h, the running time from start-up to exhaustion of alarm batteries is not less than 2.5hours. optional(2pcs)battery, Running at 2000 ml/h, the running time from start-up to exhaustion of alarm batteries is not less than 5 hours.
Alarm
Alarm signal sound pressure level
When the sound is set at lowest level, alarm signal sound pressure level ≥50dB(A)

When the sound is set at highest level, alarm signal sound pressure level ≤80dB(A)
Alarm information
VTBI near end, VTBI infused, Pressure high, Battery nearly empty, Battery empty, system error, No power supply, Reminder alarm, Standby time expired, KVO finished, Drop sensor connection, Drop error, Empty bottle, Single bubble, Cumulative Bubble, Door Open, Occlusion pre-alarm, Drop in pressure, Drug dose limits exceeded, Backup battery power exhaustion
 
Specifications
Infusion Accuracy
± 5% (± 3% with infusion set of good quality after proper calibration)
Applicable IV set
15, 20, 60drops/ml, tubing diameter: 3.5-4.5mm
Infusion rate
0.1-1200ml/h
Increment selectable: 0.1ml/h, 1ml/h, 10ml/h or 100ml/h
VTBI
0.1-9999ml, Increment: 0.1ml/h
Accumulated volume
0.1-9999ml
KVO Rate
5ml/h
Bolus Rate
1-1200ml/h (adjustable); Default: 600ml/h
Purge Rate
600ml/h
Air-in-line Detection
Mini. size of air bubble: 50ul (Levels 1, 2, 3, 4 adjustable); Default: Level 1
Occlusion Pressure
Occlusion Level Adjustable, 40-160kpa (low, middle, high selectable); Default: Low
AC Power
100-240V 50/60Hz
Built-in Battery
Li-Polyme 7.4V 1600mAh. Charging time: 8-12h with power on. Running time: 3h at rate 25ml/h
Power Consumption
25VA
On-board Battery/DC
DC 12V ± 1V
Working Conditions
Environment temperature 5C~40C Relative humidity: 10-90% (free of frost) Atmosphere pressure 86kPa~106kPa
Shell Size
130(w)x 130(h)x 80(d)mm
Weight
5 lbs.
Warranty
12 Month Warranty

GradyVet 9500 Fluid Warmer

The GradyVet 9500 is a dual line warmer for fluids, medications and blood products to improve patient absorption. The magnetic closing feature easily secures IV lines for heating on both sides. The warmer has an optional alarm and LCD screen to display the temperature in either Fahrenheit or Centigrade. The included strap allows you to conveniently treat caged animals by hanging the warmer outside of the cage. We offer a full one year warranty.
  • Full Color Downloadable PDF
  • Temperature Chart Downloadable PDF
  • Weighs 1.3 lbs
  • New with a one year warranty
  • Accepts any standard IV Set
  • LCD Display
  • Displays in Fahrenheit or Centigrade
  • Water Resistant

GradyVet IV Lines – NOW AVAILBLE!